Course curriculum

    1. Course Introduction

    1. Part I System Overview

    2. Part II Quadrupole Optics

    3. Part III Alignment Line Focus at Slit

    4. Part IV Beam Envelope

    5. Part V Aberration

    6. Part VI Manual Method Set Focus at Slit

    7. Part VII Automated LS Optics Setup

    8. Part VIII K3 Electron Scatter Test

    1. Continuum Installation and Service - Chapter 1 Introduction

    2. Continuum Installation and Service - Chapter 3 System Placement

    3. Continuum Continuum Installation and Service - Chapter 10 Appendix

    1. Introduction

    2. 1067HD FTP Imaging mode _ Align ZLP Coarse - Tune Iso Low

    3. 1067HD FTP Imaging mode _Tune SX3

    4. 1067HD FTP EELS Mode Standard Dispersion

    5. 1067HD FTP Imaging mode _Tune Imaging

    6. 1067HD FTP Line Focus Dispersion Part 1_Pre-Slit

    7. 1067HD FTP Line Focus Dispersion Part 2_Post-Slit

    8. 1067 HD FTP Line Focus Dispersion Part 3_Fine Tune

    9. 1067HD FTP Line Focus Dispersion Part 4_ Set Beam Trap and manual Zero Slit Center

    1. Drift tube calibration

    2. Spectrum offset calibration for JEOL TEM

    3. Magnification calibration

    4. Camera length calibration - Diffraction mode

    5. Camera length calibration - STEM mode using grating replica/BN sample and known convergence angle

    6. Camera length calibration - STEM mode using single crystal gold

    7. Energy constant calibration

    1. Introduction

    2. K3 Imaging 1. Load Cal Default - Check Lens Currents

    3. K3 Imaging 2. Start Acquisition - Find the Beam - Image Centering - ZLP Stability

    4. K3 Imaging 4. Slit Calibration

    5. K3 Imaging 3. Align ZLP Coarse - Deflector Tuning - Low Order Mask Cal - Low Order Mask Tune 1

    6. K3 Imaging 6. Tune Imaging Mode

    7. K3 Imaging 5. Align ZLP - Tune Focus at Slit - Cal Iso Low - Tune Iso Low - Tune SX3

    8. K3 Imaging 7. Double Focus

    9. K3 Imaging 9. Issue-Fix with Low Order Mask Tune and Cal

    10. K3 Imaging 8. Measure Isochromaticity - Measure Chromaticity - distortions - astigmatism - DFM setup

    11. K3 Spectroscopy 1. Setup - Important Information - Addition of 2 new features

    12. K3 Spectroscopy 3. Dispersion .030 ev.ch

    13. K3 Spectroscopy 2. Dispersion 90 meV.ch

    14. K3 Spectroscopy 4. Introduction of two new tools

    15. K3 Spectroscopy 5. LF Imaging Mode .9 dispersion

    16. K3 Spectroscopy 7. Dispersion 0.45 eV - LF Imaging and K3 Fine Tune

    17. K3 Spectroscopy 6. Spectrum Fine Tune .9 Dispersion

    18. K3 Spectroscopy 8. Dispersion 0.18 eV - K3 Fine Tune

    19. K3 Spectroscopy 9. DC2 correction

About this course

  • Free
  • 107 lessons
  • 15 hours of video content